Model No.: S5138
Brand Name: SHJ

Each input can be 0-5V,0-10V,0-20mA,thermistor,dry contact, open-collector input,6 isolated digital input,16 channels isolated open-collector output

S5138 is a high quality and low cost analog data acquisition module with 8 universal analog inputs. Each input can be 0-5V,0-10V,0-20mA,thermistor,dry contact, open-collector input,6 isolated digital input and 16 channels isolated open-collector digital output. The digital input can be dry contact, wet contact and open-collector, each input also can be 32-bit counter.S5138 has RS485 and rj45 two type interface,rs485 support standard Modbus RTU protocol and RJ45 support Modbus Tcpip protocol.It can easy integrate with PLC and labview with standard Modbus/Modbus Tcpip protocol

 Highlights:

l         Surge-protected analog inputs with 12-bit resolution and 100k sample speed

l         Input can be any combination of 0-5V,4-20mA,0-10V,NTC 10K thermistor, open-collector and dry contact

l         The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 6 for digital input, improve sample rate for small count input

l         Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz

l         Total 16 channels isolated open-collector digital output

l         Standard ModBus TCPIP protocol,easy work with PLC

l         Standard ModBus protocol allows for up to 254 unique devices on one RS485 network

l         A lot of spare FLASH can be used to store user's parameters

l         Can update your firmware via ISP through RS485 network, can provide any hex file to help you finish some logic control

l         DIN support available

 

 

Application:

ü         Remote data acquisition

ü         Process monitoring

ü         Industrial process control

ü         Energy management

ü         Supervisory control

ü         Security systems

ü         Laboratory automation

ü         Building automation

ü         Product testing

ü         Direct digital control

Technical data:

Analog Input Resolution--------------------------------------------------------------------------------12-bit

Analog Input Channel Number------------------------------------------------------------------------------8

Analog Input range----------------------0-5V,0-10v,0-20mA, thermistor, dry contact,open-collector

Analog Input Protection---------------------------------------------------------------------Lightning,static

Analog Input Accuracy---------------------------------------------------------------------------------±0.1%

Analog Input  Zero drift-----------------------------------------------------------------------------±3uV/℃

       Analog Input Sample Rate-----------60 sample/second(8 channels),900 sample/second(1 channel)

 

Digital Input Channel Number-----------------------------------------------------------------------------  6

Digital Input Range-------------------------------------------------------------------------------+4V~+36V

Digital Input Signal----------------------------------------------wet contact, dry contact, open-collector

Digital Input Counter Frequency-------------------------------100Hz@6channels;1000Hz@1channel

Digital Input Counter Length---------------------------------------------------------------------------32-bit

 

Output channel number-----------------------------------------------------------------------16

Output signal---------------------------------------------------------------------open-collector

Output current----------------------------------------------------------------maximum 40mA

 

       Output BUS----------------------------------------------------------------------------------Ethernet/RS485

         RS232/RS485 protocol--------------------------------------------------------------MODBUS/RTU

         Ethernet protocol------------------------------------------------------------------MODBUS/TCPIP

       Output Protection-----------------------------------------------------------------------------Lightning,static

Power input----------------------------------------------------------------------------------15~24V(AC/DC  

       Power consumption------------------------------------------------------------------------------------<0.6W

Ambient temperature:

              Operation-------------------------------------------------------------------------- -20~85℃(-4~185℉)

                   Storage---------------------------------------------------------------------------------------- -40~125℃(-40~257℉)

Ambient humidity-----------------------------------------------------------------------------------------------10%~90%RH

Material,enclosure-----------------------------------------------------------------------Flame proof plastic

Enclosure rating--------------------------------------------------------------------------------------------IP31

Colour----------------------------------------------------------------------------------------------White/Black

Size---------------------------------------------------------------------------------------------115*90*43 mm

Wiring diagram and description:

 

                                                        Top view figure

 

  

 

                                            Communication wiring diagram

 

 

 

Analog inputs wiring diagram

 

 

 

 

 

Dry contact wiring diagram

 

Dry contact wiring diagram

 

 

Isoalted digital output wiring diagram

 

 

Inputs

Each analog input can be jumper-configured in 1 of 4 ways:

²        0-5V signal

²        0-10V

²        0-20mA

²        Dry contact, thermistor, open-collector. thermistor default is 10K NTC, but can custom according to your sensor type

All digital inputs can be jumper-configured in 1 of 2 ways:

²        Wet contact input

²        Dry contact, open-collector input

PINs and LEDs

Power supply

       24VAC: power supply positive input, has reverse protection, accept AC and DC input

-           : Power supply negative input

RS485 Port

        B: Connect to B of RS485

        A: Connect to A of RS485

        R: Connect to GND for RS485

Ethernet port

               Connect to local Ethernet network through RJ45 cable

 

Inputs

       Analog:

A1 ~ A8: Analog input 1 through 8

AGND: common for analog input 1 through 8,also use for analog output

       Digital:

DVCC: Power source input for digital input 1 through 6,wet contact input available

D1 ~ D6: Digital input channel 1 through 6

DGND: common for digital input 1 through 6, available in dry input mode

Outputs

      

       Digital:

      O1~O16: Digital output channel 1 through 16

OGND: common GND for digital output 1 through 16

 

 Leds

BEAT: Will flash when system is working

Comm: Will flash when RS485 serial port communication

 

bigPhoto
 Mr. Michael Ma
Sales Manager
Tel: 86-21-54795985
Fax: 86-21-26265379
Mobile: 189 3009 2431
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Shanghai SHJ Electronic Co.,Ltd. [China (Mainland)]


Business Type:Manufacturer
City: Shanghai
Province/State: Shanghai
Country/Region: China (Mainland)

You May Like:

Product (52)